AB7692 EtherCAT Slave - Modbus RTU Slave
- Supported Modbus RTU functions: 1, 2, 3, 4, 5, 6, 8, 15, 16, 22, 23
- Modbus RTU transmission media RS485
- EtherCAT interface is DS301 v4.02 compliant
- EtherCAT interface supports CANopen objects SDOs and PDOs
- Up to 512 bytes of cyclic data in each direction (PDO)
- Up to 512 bytes of acyclic data in each direction (SDO)
- Galvanically isolated network electronics
Wysoka cena? Zaloguj się i kupuj taniej
Darmowa dostawa
Promocja cenowa na model HDR-15-5
Produkt przeznaczony wyłącznie do zastosowań profesjonalnychModele
-
Model Dostępność Gwarancja Schowek Twoja cenaTwoja cena Ilość produktów DodajAB7692EtherCAT Slave - Modbus RTU SlaveNa zamówienie Gwarancja: 3 980,00 zł4 895,40 złZaloguj się, aby poznać swoją cenę AB7692EtherCAT Slave - Modbus RTU SlaveDostępność: Na zamówienieCena netto:3 980,00 zł
Opis
The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.
The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s.
The EtherCAT Slave Interface for the Anybus X-gateway implements CANopen over EtherCAT, and exchanges up to 512 bytes of data in each direction. The interface acts as a slave node, which means it can be accessed by an EtherCAT master, but it will not initiate communication by itself. The module has two RJ45 connectors using 100 Mbit full duplex Ethernet. For configuration a XML-format device despription file is supplied by HMS
Specyfikacja
- Specyfikacja techniczna
| Size: | 126 mm x 110 mm x 42 mm |
| Power Supply: | 24 VDC (?10%) |
| Temperature: | 0-65°C |
| Current Consump: | max 300 mA |
| I/O Input: | Default 20 bytes, max 512 bytes |
| I/O Output: | Default 20 bytes, max 512 bytes |
| Mech Rating: | IP20/Nema1 |
| Config Method: | Windows Hyper Terminal |
| UL certification: | E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4 |
| ATEX certification: | ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03 |
| Power supply connect: | 2-pole 5.08 mm Phoenix pluggable screw connector |
| Modbus RTU baudrate: | 1200 Bit/s to 57 600 Bit/s |
| Modbus RTU address: | Node address 1-247 |
| Modbus RTU connector: | D-sub 9-pin female |
| EtherCAT baudrate: | 100 Mbit/s |
| EtherCAT conector: | RJ45 |
| EtherCAT config: | Configured by EtherCAT Master via XML file(provided by HMS) |
| Price Group: | A |
| Order Code: | AB7692 |
Pliki do pobrania
Polecane produkty
Polecane
ABC3090-A Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave
Polecane
ABC4090-A - Common Ethernet slave - Common Ethernet slave
Polecane
ABC4013-A PROFINET IO-Device - EtherNet/IP slave
Polecane
ABC3007-A Modbus RTU Master - EtherNet/IP Adapter