AB7814 DeviceNet Master-Interbus Slave Cu
- Complete DeviceNet 2.0 scanner implementation according to ODVA
- DeviceNet Group 2 Client/Server / UCMM support
- Manages up to 63 DeviceNet slaves
- DeviceNet Configuration via AnyBus NetTool-DN or RSNetworx
- DeviceNet Explicit peer to peer messaging, configuration consistency value. I/O Slave messaging: Bit strobe, Polling, Cyclic & Change of State (COS)
- Individually isolated Bus In and Bus Out Interbus interfaces
- Up to 10 words of Process data on Interbus
- Interbus PCP v2.0 (0, 1, 2 or 4 words)
Darmowa dostawa
Promocja cenowa na model HDR-15-5
Produkt przeznaczony wyłącznie do zastosowań profesjonalnychOpis
The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.
The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the Anybus-M module via the HMS configuration software NetTool-DN (included free of charge) or via Rockwell´s RSNetWorx.
The Interbus 2Mbit/s interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP.
Specyfikacja
- Specyfikacja techniczna
| Size: | 126 mm x 110 mm x 42 mm |
| Power Supply: | 24 VDC (?10%) |
| Temperature: | 0-65°C |
| Current Consump: | max 300 mA |
| I/O Input: | Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus) |
| I/O Output: | Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus) |
| Mech Rating: | IP20/Nema1 |
| Config Method: | Windows Hyper Terminal |
| UL certification: | E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4 |
| ATEX certification: | ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03 |
| Power supply connector: | 2-pole 5.08 mm Phoenix pluggable screw connector |
| DeviceNet baudrate: | 125-500 kbit/s |
| DeviceNet MacID: | 0-63 |
| DeviceNet connector: | 5-pole 5.08 mm Phoenix pluggable screw connector |
| Interbus Baudrate: | 500Kbit/s or 2Mbit/s |
| Interbus connectors: | D-sub 9-pin ? Bus In male, Bus Out female |
| Accessory order: | 018021 (NetTool-DN configuration tool for DeviceNet) |
| Price group: | C |
| Order Code: | AB7814 |
Pliki do pobrania
Polecane produkty
Polecane
ABC3007-A Modbus RTU Master - EtherNet/IP Adapter
Polecane
ABC4011-A - EtherNet/IP adapter - Modbus TCP server
Polecane
ABC4090-A - Common Ethernet slave - Common Ethernet slave
Polecane
ABC3090-A Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave