Polecane
ABC4013-A PROFINET IO-Device - EtherNet/IP slave
Koszyk

AB7824 ASI Master-FIP Slave
Darmowa dostawa
Promocja cenowa na model HDR-15-5
Produkt przeznaczony wyłącznie do zastosowań profesjonalnych| Model | Dostępność | Gwarancja | Schowek | Twoja cena | Twoja cena | Ilość produktów Dodaj |
|---|---|---|---|---|---|---|
| AB7824 ASI Master - FIP Slave | Na zamówienie | Gwarancja: | 0,00 zł - | - |
The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.
The AS-Interface Master for the Anybus X-gateway implements an extended AS-Interface master (M4), and complies to version 3.0 of the AS-I Complete Specification. It supports up to 62 slaves with a maximum of 248 digital input and 186 output signals. It also supports 124 analog values. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a 2-pin pluggable screw connector. The Master supports intelligent auto-configuration via the on-board configuration button or manual configuration via a terminal program such as Hyper Terminal for Windows. The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc.
The FIPIO interface is based an embedded AnyBus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer connection on the module provides a isolated fieldbus interface.
| Size: | 126 mm x 110 mm x 42 mm |
| Power Supply: | 24 VDC (?10%) |
| Temperature: | 0-65°C |
| Current Consump: | max 300 mA |
| I/O Input: | Default 20 bytes, max 64 bytes (248 digital inputs on ASI) |
| I/O Output: | Default 20 bytes, max 64 bytes (186 digital outputs on ASI) |
| Mech Rating: | IP20/Nema1 |
| Config Method: | Windows Hyper Terminal |
| UL certification: | E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4 |
| ATEX certification: | ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03 |
| Power supply connector: | 2-pole 5.08 mm Phoenix pluggable screw connector |
| AS-I baudrate: | 167 kbit/s |
| AS-I connector: | 2 x 2-pole 5.08 mm Phoenix pluggable screw connectors |
| FIPIO baudrate: | 1 Mbit/s |
| FIPIO address: | Node address 0-99 |
| FIPIO connector: | D-sub 9-pin male |
| Price Group: | C |
| Order Code: | AB7824 |
Polecane