AB7866

AB7866 ControlNet Slave - Interbus Cu Slave

Producent: Anybus
Producent: Anybus

AB7866 ControlNet Slave - Interbus Cu Slave

  • Multicasts of both inputs and peer-to peer data on ControlNet
  • ControlNet Media redundancy
  • ControlNet Specification version: Communications Adapter profile 12
  • Individually isolated Bus In and Bus Out Interbus interfaces
  • Up to 10 words of Process data on Interbus
  • Interbus PCP v2.0 (0, 1, 2 or 4 words)
Cena od 7 997,00 zł netto

Wysoka cena? Zaloguj się i kupuj taniej

Na zamówienie

Darmowa dostawa od 500 zł

Pokaż 1 model

Promocja cenowa na model HDR-15-5

Produkt przeznaczony wyłącznie do zastosowań profesjonalnych
AB7866

AB7866

Modele

Opis

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.

The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc

The Interbus 2Mbit/s interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP.

Specyfikacja

  • Specyfikacja techniczna
Size: 126 mm x 110 mm x 42 mm
Power Supply: 24 VDC (?10%)
Temperature: 0-65°C
Current Consump: max 300 mA
I/O Input: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 450 bytes as I/O on ControlNet)
I/O Output: Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 450 bytes as I/O on ControlNet)
Mech Rating: IP20/Nema1
Config Method: Windows Hyper Terminal
UL certification: E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4
ATEX certification: ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03
Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector
ControlNet baudrate: 5Mbit/s
ControlNet MacID: 1-99
ControlNet connector: Dual BNC coaxial connectors
ControlNet config.: Configured by ControlNet Scanner via EDS file (provided by HMS)
Interbus Baudrate: 500Kbit/s or 2Mbit/s
Interbus connectors: D-sub 9-pin ? Bus In male, Bus Out female
Price Group: C
Order Code: AB7866