AB7866 ControlNet Slave - Interbus Cu Slave
- Multicasts of both inputs and peer-to peer data on ControlNet
- ControlNet Media redundancy
- ControlNet Specification version: Communications Adapter profile 12
- Individually isolated Bus In and Bus Out Interbus interfaces
- Up to 10 words of Process data on Interbus
- Interbus PCP v2.0 (0, 1, 2 or 4 words)
Wysoka cena? Zaloguj się i kupuj taniej
Darmowa dostawa od 500 zł
Promocja cenowa na model HDR-15-5
Produkt przeznaczony wyłącznie do zastosowań profesjonalnychModele
-
Model Dostępność Gwarancja Schowek Twoja cenaTwoja cena Ilość produktów DodajAB7866ControlNet Slave - Interbus Cu SlaveNa zamówienie Gwarancja: 7 997,00 zł9 836,31 złZaloguj się, aby poznać swoją cenę AB7866ControlNet Slave - Interbus Cu SlaveDostępność: Na zamówienieCena netto:7 997,00 zł
Opis
The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.
The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc
The Interbus 2Mbit/s interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP.
Specyfikacja
- Specyfikacja techniczna
Size: | 126 mm x 110 mm x 42 mm |
Power Supply: | 24 VDC (?10%) |
Temperature: | 0-65°C |
Current Consump: | max 300 mA |
I/O Input: | Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 450 bytes as I/O on ControlNet) |
I/O Output: | Default 20 bytes, max 512 bytes (max 20 bytes as I/O on Interbus, max 450 bytes as I/O on ControlNet) |
Mech Rating: | IP20/Nema1 |
Config Method: | Windows Hyper Terminal |
UL certification: | E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4 |
ATEX certification: | ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03 |
Power supply connector: | 2-pole 5.08 mm Phoenix pluggable screw connector |
ControlNet baudrate: | 5Mbit/s |
ControlNet MacID: | 1-99 |
ControlNet connector: | Dual BNC coaxial connectors |
ControlNet config.: | Configured by ControlNet Scanner via EDS file (provided by HMS) |
Interbus Baudrate: | 500Kbit/s or 2Mbit/s |
Interbus connectors: | D-sub 9-pin ? Bus In male, Bus Out female |
Price Group: | C |
Order Code: | AB7866 |
Pliki do pobrania
Polecane produkty
Polecane
Moduł komunikacyjny BACnet/IP 2-port
Polecane
ABC4011 - EtherNet/IP adapter - Modbus TCP server
Polecane
ABC4090 - Common Ethernet slave - Common Ethernet slave
Polecane
ABC3090 Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave