AB7871

AB7871 CC Link Slave - ControlNet Slave

Producent: Anybus
Producent: Anybus

AB7871 CC Link Slave - ControlNet Slave

  • Multicasts of both inputs and peer-to peer data on ControlNet
  • ControlNet Media redundancy
  • ControlNet Specification version: Communications Adapter profile 12
  • Uses up to 4 occupied stations on CC-Link - configurable size
  • Uses the CC-Link PLC profile for data exchange
  • Support for CC-Link version 2.0 with extended data
Cena od 7 008,00 zł netto

Wysoka cena? Zaloguj się i kupuj taniej

Na zamówienie

Darmowa dostawa

Pokaż 1 model

Promocja cenowa na model HDR-15-5

Produkt przeznaczony wyłącznie do zastosowań profesjonalnych
AB7871

AB7871

Modele

Opis

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.

The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc

Specyfikacja

  • Specyfikacja techniczna
Size: 126 mm x 110 mm x 42 mm
Power Supply: 24 VDC (?10%)
Temperature: 0-65°C
Current Consump: max 300 mA
I/O Input: Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
I/O Output: Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
Mech Rating: IP20/Nema1
Config Method: Windows Hyper Terminal
UL certification: E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4
ATEX certification: ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03
Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector
ControlNet baudrate: 5Mbit/s
ControlNet MacID: 1-99
ControlNet connector: Dual BNC coaxial connectors
ControlNet config.: Configured by ControlNet Scanner via EDS file (provided by HMS)
CC-Link baudrate: 156kbps to 10Mbps
CC-Link address: Station 1-64
CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector
CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)
Price Group: C
Order Code: AB7871

Pliki do pobrania

Polecane produkty

Skontaktuj się z ekspertem
Telefonicznie +48 22 773 79 37
Przez formularz Wypełnij formularz