AB7875

AB7875 FIP Slave -Interbus Fo Slave

Producent: Anybus
Producent: Anybus

AB7875 FIP Slave -Interbus Fo Slave

  • Supports both FIP and WorldFIP standards
  • FIPIO profile FEDP (Extended Device Profile), class 0
  • Transformer isolated FIP interface
  • Up to 10 words of Interbus Process data
  • PCP v2.0 (0, 1, 2 or 4 words)
  • Fiber Optic features FSMA standard connectors conforming to IEC874-2 and DIN47258
  • Based on OPC chipset with support for optical diagnostics
  • Transmission Media: Plastic fibre, core 180um, clad 1000um: HCS (glass) fibre, core 200um, clad 230 um
Na zamówienie

Darmowa dostawa od 500 zł

Pokaż 1 model

Promocja cenowa na model HDR-15-5

Produkt przeznaczony wyłącznie do zastosowań profesjonalnych
AB7875

AB7875

Modele

  • ModelDostępnośćGwarancjaSchowek
    Twoja cena
    Twoja cena
    AB7875
    FIP Slave - Interbus Fo Slave
    Na zamówienie Gwarancja:
    0,00 zł
    -
    -
    AB7875
    FIP Slave - Interbus Fo Slave
    Dostępność: Na zamówienie
    Cena netto:
    -
    -

Opis

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.

The FIPIO interface is based an embedded Anybus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer connection on the module provides a isolated fieldbus interface.

The Interbus 2MBit/s interface with a Fiber Optic bus-interface is an important complement to the standard module for copper based cabling. The Fiber Optic module is based on the OPC chipset from Pheonix, which gives support for optical diagnostics. This means the unit has a high EMC immunity and also a very low EMC emission. The Interbus interface 2Mbit/s module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called ?Process Data?, and one through a somewhat slower protocol called PCP, which is mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP.

Specyfikacja

  • Specyfikacja techniczna
Size: 126 mm x 110 mm x 42 mm
Power Supply: 24 VDC (?10%)
Temperature: 0-65°C
Current Consump: max 300 mA
I/O Input: Default 20 bytes, max 64 bytes (max 20 bytes as I/O on Interbus)
I/O Output: Default 20 bytes, max 64 bytes (max 20 bytes as I/O on Interbus)
Mech Rating: IP20/Nema1
Config Method: Windows Hyper Terminal
UL certification: E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4
ATEX certification: ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03
Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector
Interbus Baudrate: 500Kbit/s or 2Mbit/s
Interbus connectors: HFBR-2505C and HFBR-1505C
FIPIO baudrate: 1 Mbit/s
FIPIO address: Node address 0-99
FIPIO connector: D-sub 9-pin male