AB7897

AB7897 CANopen Slave - CC Link Slave

Producent: Anybus
Producent: Anybus

AB7897 CANopen Slave - CC Link Slave

  • CANopen PDO and SDO data objects supported
  • CANopen Unscheduled data exchange support
  • CANopen Watch-dog timer
  • CANopen profile DS-301
  • Uses up to 4 occupied stations on CC-Link - configurable size
  • Uses the CC-Link PLC profile for data exchange
  • Support for CC-Link version 2.0 with extended data
Cena od 3 980,00 zł netto

Wysoka cena? Zaloguj się i kupuj taniej

Na zamówienie

Darmowa dostawa

Pokaż 1 model

Promocja cenowa na model HDR-15-5

Produkt przeznaczony wyłącznie do zastosowań profesjonalnych
AB7897

AB7897

Modele

Opis

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.

The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave?s data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation (CANopen conformance: CIA DS-301 V3.0) and has proven conformance and interoperability with leading PLC´s, SoftPLC´s, HMI´s etc

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc

Specyfikacja

  • Specyfikacja techniczna
Size: 126 mm x 110 mm x 42 mm
Power Supply: 24 VDC (?10%)
Temperature: 0-65°C
Current Consump: max 300 mA
I/O Input: Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
I/O Output: Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
Mech Rating: IP20/Nema1
Config Method: Windows Hyper Terminal
UL certification: E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4
ATEX certification: ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03
Power supply connector: 2-pole 5.08 mm Phoenix pluggable screw connector
CANopen baudrate: 10 kbit/s to 1 Mbit/s
CANopen connector: D-sub 9-pin male
CANopen address: Node address 1-99
CANopen config.: Configured by CanOpen Master via EDS file (provided by HMS)
CC-Link baudrate: 156kbps to 10Mbps
CC-Link address: Station 1-64
CC-Link connector: 5-pole 5.08 mm Phoenix pluggable screw connector
CC-Link config.: Configured by CC Link Master via CSP Config file (provided by HMS)
Price Group: A
Order Code: AB7897